Single-Point Lubricators

Memolub HPS - Single Point Automatic Lubricator | Power Lube Industrial

MEMOLUB® HPS
Single-Point Lubricator

The MEMOLUB® HPS is a diverse electromechanical lubricator that can be installed on a single lube point or coupled with a progressive distribution valve to lubricate from 2 to 12 points. You can depend on Memolub HPS automatic single point lubricators.
  • Reliable lubrication 24 hours a day, reduce equipment downtime
  • Reusable pump - low cost replaceable lube cartridges
  • 52 programmable duration settings
  • Battery powered - no wiring needed
  • 2 year lubricator warranty

Memolubs are decentralized lubricators for Conveyors, Cranes, Crushers, Pumps, Elevators, Lifts, Trains and Hoists, Industrial Robots, Rollers and Drive Assemblies, Fans and Blowers, Motors and Generators, Chains and Rails, Food Processing Equipment and more!

Memolubs solve lubrication challenges in virtually all industries from Automobile manufacturing to Mining and every thing in between.

Call our helpful Power Lube Industrial staff and we’ll work with you to determine the best lubricator model and offer you many lubricant options for your application. We stock over 200 of the most commonly used lubricants.

Part Numbers:
MLHPS120 - MEMOLUB HPS Model 120cc
MLHPS240 - MEMOLUB HPS Model 240cc
MLHPS480 - MEMOLUB HPS Model 480cc

Lubricant cartridges & battery packs sold separately

How to order your MEMOLUB® HPS lubricator - click here .pdf

Automatic Bearing Lubricator

The MEMOLUB® HPS single point lubricator automatically delivers a small, precise amount of lubricant at regular intervals for an continuous supply of fresh lubricant directly to your lube point. Prevents over and under lubrication problems related to manual lubrication.

  • 120, 240 or 480cc lubricant capacity 350psi max output pressure from start to finish
  • Use with Oil or Grease (up to NLGI #2)
  • Remote mount up to 40 feet from the lube point
  • Use in a wide temperature range of applications
Memolub HPS - Pillow Block Bearing

All MEMOLUB HPS models use the same motor base assembly, making it easy to convert from one lubricant capacity to another by simply purchasing a low cost transparent housing kit.

Simple MEMO Programming

The MEMOLUB® HPS daily lubricant output is programmed using the simple MEMO system. The MEMO can be programmed to control both the frequency of lube cycles and the volume of lubricant discharged. Once the MEMO is programmed and installed any MEMOLUB® HPS lubricator will recognize the settings.

Memolub Memo System - Basic Frequency settings
R
Red
W
White
B
Black
Colored timing rings Strokes per day CC's per stroke Daily output in CC's Model 120 months to empty Model 240 months to empty Model 480 months to empty
R
W
B
24 0.63 15.1 N/A 0.5 1
R
W
B
12 0.63 7.6 0.5 1 2
R
W
B
4 0.63 2.5 1.5 3 6
R
W
B
2 0.63 1.3 3 6 12
R
W
B
1.5 0.63 1 4 8 16
R
W
B
1 0.63 0.6 6 12 24
R
W
B
0.5* 0.63 0.3 12 24 N/A
* Lubrication cycles every other day (48 hours)
Memolub Memo, Spacer & Timing Rings | Power Lube Industrial

Basic Frequency Settings

There are 7 basic frequency settings that are suitable for most industrial applications.  They are programmed by installing one or a combination of the three colored timing rings into the ring holder attached to the brass fitting. When you screw the MEMOLUB® lubricator onto the brass fitting, the timing rings depress the switches on the bottom of the lubricator. This activates the lubricator program.

Memolub Memo, Spacers & Timing Rings

Adjusting the Volume of Lubricant

Included in the MEMO kit is eight spacer washers for adjusting the amount of lubricant discharged per lube cycle. Installing one, or a combination of all eight washers, into the brass MEMO fitting will limit the stroke length of the piston inside the lubricator.

Product Resources:

Contact us to learn more about the easy-to-use, effective MEMOLUB lubricator.

Memolub HPS Technical Drawing | Power Lube Industrial
Memolub HPS Technical Drawing | Power Lube Industrial
  1. Lower temperatures can be achieved by using a low temperature grease and cold-weather battery packs
  2. Splitter Blocks cannot be used with oil, and are limited to 7 lubricant output settings.
  3. Maximum lube line length is dependent on ambient temperature, grease type and application back pressure.
Sorry, your query returned no results! The category you have chosen has no content at this time. Please try the "All Downloads" category.

Pages

Memolub
Application Case Study
Case Study No. 818 - Rotating Furnace
Memolub - Rotating Furnace | Power Lube Industrial
Industry:
Chemical
Application:
Dryers
Issue:
Oil lubrication dispensed by an inadequate central lubrication system leading to over-lubrication, pollution, wear of the rollers and heavy vibration of the furnace.
Solution:
Installed MEMOLUB® GIGA lubricators initially set at a 15 day setting. After further inspection the setting was changed to 1 month. After 2 months, wear has been reduced along with furnce vibration. No more spillage and pollution. Shown here are MEMOLUB's protected with plastic bags against the harsh enviroment.

Pages

Memolub
Application Case Study
Case Study No. 808 - Lubrication for Rollers and Drive Assembly
Memolub Multi Point SystemMemolub Multi Point SystemMemolub Multi Point System -- Rollers & Drive Assembly - Municipal Water Treatment Facility
Application:
Rollers & Drive Assembly - Municipal water treatment facility
Industry:
Utilities
Background:
Facility was using gas-generated, electrochemical lubricators on each lube point.
Issue:
These lubricators produced inconsistent lubrication due to insufficient output pressure and temperature variations.
Solution:
Solution 1 : Four Giga 8-point MEMOLUB® lubrication systems replaced 32 electrochemical lubricators. These systems were installed to lubricate the rollers on the water softener equipment. While the equipment turns, the MEMOLUB® automatically delivers a consistent, time-controlled, metered quantity of lubricant to all rollers. Solution 2: One Mega 3-point MEMOLUB® lubrication system was installed to lubricate the drive gear assembly. Two outlets lubricate the drive gear bearings and one outlet drops grease directly onto the open gear. Solution 3: One 2 point MEMOLUB® Splitter system was installed to apply grease directly to the top and side of inner rail using brushes.
Worth Mentioning:
Lubrication while the machine is in operation ensures that the lubricant is evenly and optimally distributed. This results in decreased lubricant consumption and increased machine life. In addition, the installation of a MEMOLUB multi-point system drastically reduces the likelihood of contamination from excess grease.

Pages

Call to Order:
(800) 635-8170
Memolub
  HPS Related Products
Product Description Item Number
L-Bracket Mount Kit IPMLLBK-1
  • L-Bracket Kit
  • Mount 2 Memolubs
IPMLLBK-2
Memolub Lubricant Refill Kits
See MEMOLUB Replacement Kits page
Memolub Standard and Mega Dust Cover
  • Memolub Standard and Mega Dust Cover
  • Fits Standard Model 120 and Mega Model 240
IPM-DCSM-1