Single-Point Lubricators

Memolub PLCd | Power Lube Industrial

MEMOLUB® 24VDC-PLCd
Single-Point Lubricator

The MEMOLUB 24VDC-PLCd-Control model electromechanical lubricator is the ultimate in single-point or multi-point lubrication. Gives you complete control of your lubrication program.
  • Integrates with Programmable Logic Controllers
  • Control Frequency and Duration of each Output Cycle
  • Use in a Wide Variety of Applications; Mobile Equipment, Robots, Conveyors and OEM …….
  • Powered by an External 24VDC Power Supply
  • Replaceable Cartridge

Part Numbers:
MLPLCD120 - MEMOLUB PLCD Model 120cc
MLPLCD240 - MEMOLUB PLCD Model 240cc
MLPLCD480 - MEMOLUB PLCD Model 480cc

Lubricant cartridges & battery packs sold separately

How to order your MEMOLUB® PLCd lubricator - click here .pdf

Memolub PLCd - Pillow Block | Power Lube Industrial
The MEMOLUB® PLCd is powered and programmed by your PLC and automatically delivers a small, precise amount of lubricant at regular intervals for an continuous supply of fresh lubricant directly to your lube point. Prevents over and under lubrication problems related to manual lubrication.
  • 120, 240 or 480cc lubricant capacity
  • 350psi max output pressure from start to finish
  • Use with Oil or Grease (up to NLGI #2)
  • Remote mount up to 40 feet from the lube point
Memolub PLCd - Pillow Block Bearing
Memolub - Power-Thru-Memo | Power Lube Industrial
Power Through Memo & Washers

The MEMOLUB® 24VDC-PLCd Control lubricator has a unique design utilizing a Power-Through Memo which contains the electrical connections needed to power the unit. This gives the user the ability to quickly remove the lubricator for fast lubricant cartridge change-out while avoiding need to disconnect the electrical connections.

A 5-foot extension cable on the Power-Through Memo is connected to a PLC-controlled power supply. The PLC program controls the frequency of lubrication output cycles, which may be based upon elapsed clock hours, machine cycles, a count of parts produced, or other desired criteria.

Product Resources:

Contact us to learn more about the easy-to-use, effective MEMOLUB lubricator.

Memolub PLCd Technical Drawing | Power Lube Industrial
Memolub PLCd Technical Drawing | Power Lube Industrial
  1. Lower temperatures can be achieved by using a low temperature grease and cold-weather battery packs
  2. Splitter Blocks cannot be used with oil, and are limited to 7 lubricant output settings.
  3. Maximum lube line length is dependent on ambient temperature, grease type and application back pressure.
Sorry, your query returned no results! The category you have chosen has no content at this time. Please try the "All Downloads" category.

Pages

Memolub
Application Case Study
Case Study No. 031519 - Lubricating an Automated Palletiser
Memolub Automatic Lubricator -- Palletising Robot Lubrication
Industry:
Food & Beverage
Application:
Elevators/Lifts/Conveyors
Background:
Equipment was previously being manually lubricated with a grease gun. Depending on what maintenance tech performed the task, over- and under-lubrication were common-place, if done at all. Over-lubrication was especially a problem because often bearings were pushed out of the linear slides, caus-ing premature failure. The customer would spend thousands annually in repair costs as a result.
Solution:
We installed 2 MEMOLUB® ONE single-point lubricators per palletiser to supply constant lubrication to the linear slide bearings. Pro-gramming the lubricators to dispense per the manufacturer’s specs removed human inconsistency from the maintenance equa-tion thereby extending bearing life. An add-ed bonus was the ability to lubricate while the equipment is still in operation.
Results:
Reduced downtime and extended bearing life.
Worth Mentioning:

Pages

Memolub
Application Case Study
Case Study No. 602
Memolub -- Bagging Machine Seals | Power Lube IndustrialMemolub - Bagging Machine Seals | Power Lube IndustrialMemolub - Bagging Machine Seals | Power Lube Industrial
Application:
General Production Equipment
Industry:
Cement
Issue:
Lubrication was done manually, and only when the machine was able to be shut down. Also, cement contamination introduced at the zerks caused seal blockage and the turbine stopped from the resulting pressure build-up.
Solution:
Two 5-Point MEMOLUB lubrication systems were installed to service all the lube points automatically, at regular intervals. Lubricators were placed in a convenient location so that the lube cartridges could be changed without shutting down the machine.

Pages

Call to Order:
(800) 635-8170
Memolub
  PLCd Related Products
Product Description Item Number
L-Bracket Mount Kit IPMLLBK-1
  • L-Bracket Kit
  • Mount 2 Memolubs
IPMLLBK-2
Memolub Lubricant Refill Kits
See MEMOLUB Replacement Kits page
Memolub Standard and Mega Dust Cover
  • Memolub Standard and Mega Dust Cover
  • Fits Standard Model 120 and Mega Model 240
IPM-DCSM-1
Pre-filled Nylon Tubing