MEMOLUB® Power-Through MEMO

The MEMOLUB® Power-Through MEMO is used exclusively with the MEMOLUB® PLCD model lubricator. Unlike standard MEMO units that rely on mechanical timing rings to determine lubrication frequency, the Power-Through MEMO receives electrical power from an external source, such as a PLC (Programmable Logic Controller), which determines when a lubrication cycle should occur.

PLCD MEMO 300

How the Power-Through MEMO Connects to the MEMOLUB® PLCD

The Power-Through MEMO creates a direct electrical connection between your PLC and the MEMOLUB® PLCD lubricator—enabling fully programmable lubrication with no timing rings.

Electrical Connection

  • PLCD Lubricator Contact Pins
    Two contact pins on the bottom of the MEMOLUB® PLCD align with conductive rings inside the MEMO.
  • Power-Through MEMO Rings
    The MEMO’s black ring holder contains two internal contact rings connected to a 2-wire cable that receives 24V DC from your PLC.
  • Automatic Activation
    When the PLCD is screwed onto the MEMO, the pins and rings make contact. A pulse from the PLC completes the circuit, triggering one lubrication stroke.
PLCD Rings and Pins c

MEMOLUB® PLCD: Volumetric Settings

Each MEMOLUB® PLCD lubricator comes with a set of stroke-limiting washers that let you control how much lubricant is dispensed with each cycle. This gives you the flexibility to adjust the output to match your specific needs.

  • With no washers installed, the unit delivers 0.6 cm³ of lubricant per cycle.
  • Each washer you add slightly reduces the amount—by 0.04 cm³ per washer.
  • You can use up to 8 washers total, including a special locking washer that holds the others in place.
  • If you're only using one washer, make sure it's the locking washer.
PLCD Washers web