GREASOMATIC 363x544 PLI

GREASOMATIC®96 KNOWLEDGE BASE

Dimensions

Greasomatic Dimentions 1

Greasomatic Dimentions 2

Settings

Dial Setting Daily Output Discharge Period
1 4 cc 1 month
2 2 cc 2 months
3 1.3cc 3 months
4 1 cc 4 months
6 0.7 cc 6 months
8 0.5 cc 8 months
12 0.3 cc 12 months

Average Ambient Temperature Chart

The normal discharge durations of 1, 2, 3, 4, 6, 8 or 12 months apply at an ambient temperature of 68°F (+20°C). Output and discharge durations will vary if the GREASOMATIC operates at a higher or lower temperature. The table below illustrates the output and discharge durations at varied temperatures.

Dial Setting +32°F +50°F +68°F +86°F +104°F
1 1 cc daily for 4 months 2 cc daily for 2 months 4 cc daily for 1 month 8 cc daily for 0.5 months Not recommended
2 0.5 cc daily for 8 months 1 cc daily for 4 months 2 cc daily for 2 months 4 cc daily for 1 month 6 cc daily for 0.7 months
3 0.3 cc daily for 12 months 0.7 cc daily for 6 months 1.3 cc daily for 3 months 2.7 cc daily for 1.5 months 4 cc daily for 1 month
4 0.25 cc daily for 16 months 0.5 cc daily for 8 months 1 cc daily for 4 months 2 cc daily for 2 months 3 cc daily for 1.3 months
6 0.2 cc daily for 24 months 0.3 cc daily for 12 months 0.7 cc daily for 6 months 1.3 cc daily for 3 months 2 cc daily for 2 months
8 Not recommended 0.25 cc daily for 16 months 0.5 cc daily for 8 months 1 cc daily for 4 months 1.5 cc daily for 2.7 months
12 Not recommended 0.2 cc daily for 24 months 0.3 cc daily for 12 months 0.7 cc daily for 6 months 1 cc daily for 4 months

INSTALATION

Grease Installation

  • 1

    On first installation, use a hand grease gun and the same type of lubricant to pre-charge all fittings, lines and the bearing. The thread of the GREASOMATIC® is 1/4 BSPT and can be adapted for other thread sizes using standard adapters.

  • 2

    Activate Greasomatic (see below)

Oil Installation

  • A

    Install the unit with the outlet in the up position and using a remote line to the bearing.

  • B

    Install a check valve on the outlet of the GREASOMATIC® to prevent the oil from running out.

ACTIVATION

  • 1

    Greasomatic dial 001 188x188 2

    Turn the control knob clockwise so the arrow is pointing to the desired monthly setting. If you turn the control knob to far and pass your de- sired setting, you can turn the knob counterclockwise back to zero and start again.

  • 2

    Greasomatic dial 001 188x188 2

    Press the red button until it is flush with the top surface. Once the red button is pressed the discharge rate can not be changed.

  • 3

    Greasomatic dial 001 188x188 2

    Rotate the black control knob clockwise 10 to 12 turns. This releases the galvanic element into the liquid electrolyte, thus activating the GREASOMATIC®.

Specifications

Housing Design Plastic Body and Thread
Dimensions 2.9" x 4.7" (74mm x 120mm)
Capacity 120cc (4 oz)
Drive Electrochemical
Electrolyte Liquid Mildly Acidic Organic Acid
Temperature Range 32°F to 140°F (0°C to 60°C)
Max Pressure Build-Up 73 psi (5 bar)
Installation Thread 1/4 BSPT (Adapters Available)
Discharge Period 1, 2, 3, 4, 6, 8, or 12 months
Compatible Lubricants Oil and Greases (up to NLGI2)
Tech drawing

Technical Drawing

Download
Trac

ATEX Certification

Download
Cebralis

Cerberus Certification

Download
SDS Greaomatic

Greasomatic SDS

Download
HOW TO ORDER GR120

HOW TO ORDER A GREASOMATIC

Download

REGULATORY INFORMATION

SYMBOL Description
Heart -1; Flammability -1; Reactivity -0; Special - -